The extent of work services under the contract include all items shown on the drawings, indicated in companion with specifications, not withstanding the fact that such items have been omitted from the price schedule.
Parameter | SOLR-300 | SOLR-500* | SOLR-1000 | Unit | |
Maximum DC Power | 2 x 180 | 600 | 2 x 600 | kW | |
Maximum DC Voltage | 1000 | V | |||
MPPT Operating Range | 560-800 | 600-850 | 600-850 | V | |
Maximum DC Current | 570 | 855 | 1710 | A | |
Nominal AC o/p Power | 300 | 500 | 1000 | kW | |
Nominal AC Voltage | 380 | 400 | 400 | V | |
Nominal AC Current | 456 | 723 | 1445 | A | |
DPF(@ rated AC power) | > .99 | - | |||
THDi(@ rated AC Power) | < 3 | % | |||
Maximum Efficiency | 98.3 | % | |||
DC Side Protection | Ground Fault, DC Reverse Current, Over Voltage, Over Current | ||||
AC Side Protection | Anti-islanding, Over/Under Voltage, Over/Under Frequency, Over Current | ||||
Grid assistance | Reactive/Power Factor Control, Fault Ride Through |
Parameter | SOLR-300 | SOLR-500* | SOLR-1000 | Unit |
Ambient temperature | -10ᵒC to 50ᵒC | C | ||
Dimension (L x W x H) | 1200 x 800 x 1800 | Mm | ||
Weight (approx.) | 1000 | 1400 | 2100 | Kg |
Ingress protection | IP 31 | - | ||
Relative Humidity (non-condensing) | 15% - 95 | % | ||
Maximum Altitude(above sea level) | 2000 | 2000 | 2000 | M |
User Interface | 7 inch colour Touch-Screen, Emergency Shut-off Button | |||
Communication | Modbus (RS485/RS232C), Optional Modbus (TCP/IP) | |||
Compliance requirements | Electrical safety, EMC, Environmental, Efficiency measurement, Anti-islanding requirements as per relevant IEC standards |